OpenPlant Isometrics Manager Help

Isometric Style Configuration - Component Placement

The configurations in this option are shown below.
SettingDescription
Pipe Symbology This Symbology defines settings for line used to draw pipe.
  • Line Color: Defines color of the line used to draw pipe. Click on Browse button to open Color Table and select any color from the color table.
  • Line Style: Select line style from the list for the line.
  • Line Weight: Select line weight from the list for the line.
Continuation Symbology These settings are for elements that are not really part of the current iso sheet but are included just to give an idea of the continuing pipe work on another sheet.

These element are not annotated and do not show up in the BOM.

(See the field descriptions for Pipe Symbology above.)

Dotted Pipework Symbology The options under this section define "Existing" components. The components are existing and "New" components are usually connected to them. (For instance, existing components may be used when an existing plant is re-vamped.)

These elements are normally not annotated except for the tie-in point and never show up in the BOM.

(See the field descriptions for Pipe Symbology above.)

Failed Cell Symbology If cell does not found in cell library, it is denoted in isometric drawing using settings in Failed Cell Symbology.

(See the field descriptions for Pipe Symbology above.)

Pipe Level Name Select level from the list to define Pipe Level.

When finished making any changes in the fields, click Save to apply the changes.

The Undo button will undo any changes made.
Note: The Save and Undo buttons only enable when changes are made.